Power: | 3500W | Dimensions: | 20-800mm |
---|---|---|---|
Usage: | Pipe Fittings Electrofusion | After-sales Service Provided: | Free Spare Parts, Field Installation, Commissioning And Training, Field Maintenance And Repair Service, Online Support, Video Technical Support |
Warranty: | 1 Year | Product Name: | Electrofusion Machine |
Quality of joint depends on the following instructions which have be followed carefully.
HANDLING OF PIPES & FITTINGS
When fusing, temperature of pipes & fittings have to be similar to ambient temperature measured by machine’s probe.
Therefore they cannot be exposed to strong wind or direct sunlight : their temperature may vary consistently from ambient temperature, affecting negatively fusion (pipe & fittings insufficient or excessive fusion). In case of high temperature, keep pipe & fittings away from direct sunlight and wait until their temperature is similar to ambient temperature.
PREPARATION Cut pipe’s edges straight, using special pipe cutters. Carefully try to eliminate pipe’s and fittings bends or ovalizations. CLEANINGCarefully scrape oxidized layers on pipe’s or fitting’s edges with special pipe scrapers. Make sure scraping is uniform and complete over surfaces to be fused exceeding the middle of the fitting of about 1 cm; lack of this type of operation causes a superficial fusion only, since it prevents molecular interpenetration of parts and affects fusion’s result. Scraping methods like sand paper, emery wheel must be avoided.
Take out coupler from its protecting packaging, clean the interior according to manufacturer’s instructions.
POSITIONING
Insert pipe’s edges into the coupler.
It is necessary to use an aligner for:
- making sure parts are steady during fusion and cooling phase;
- avoid any sort of mechanical stress on the joint during fusion cycle and cooling; FUSION Fusion area should be protected from strong weather conditions , such as humidity, temperatures lower that -10°C or over +40°C, strong wind, direct sunlight.Pipes & fittings used have to be of the same material or compatible material. Compatibility between materials have to be guaranteed by manufactured.
COOLINGCooling time depends on diameter of coupler and ambient temperature. It is important to follow times given by manufacturer of couplers used.
To avoid mechanical stress on the joint (bending, tractions, twisting) disconnect cables and aligners only when joint has completely cooled down.
Model | 160 | 315 | 400 | 630 | 800 | |
Working Range | 20-160mm | 20-315mm | 20-400mm | 20-630mm | 20-800mm | |
Materials | PE/PP/PPR | |||||
Dimendions mm | 200*250*210 | 358*285*302 | 358*285*302 | 358*285*302 | 358*285*302 | |
Weight | 7Kg | 21kg | 23Kg | 23kg | 23kg | |
Rated voltage | 220VAC-50/60Hz | |||||
Rated power | 1300W | 2700W | 3100W | 3100W | 3500W | |
Working power | -10℃-40℃ | |||||
Output voltage | 8-48V | |||||
Max.output current | 60A | 80A | 100A | 100A | 100A | |
Protection degree | IP54 | |||||
Connectors | 4.7mm/4.0mm | |||||
Memory | 325 | 4000 | 4000 | 4000 | 4000 |
Scroll main menu until arriving to
SETUP AND UTILITIES.
Press ENTER to access next step.
Select“Traceability”using keys C (ÙÚ). Press ENTER Press keys C (× Ø) to activate or deactivate traceability.Press ENTER to save settings and go back to menu.
Press STOP to go back to main menu.